Reliable Control Zone Kits that include the Low Flow Valve, the only valve on the market that can handle low flows (below (3gpm) without weeping.

Shorter kits with only two components (valve plus pressure-regulating filter) mean that you can fit more Control Zone Kits in a valve box, saving time and money.

These PR Filter kits provide on/off control, filtration, and pressure regulation with fewer components; so there is less chance of leakage at the connections, both at installation and over the life of the system.

Three-year trade warranty.


XCZLF-100-PRF
1" Low Flow Valve with 1" PR
RBY Filter (Assembled)
Flow: 0.20 to 10 gpm


XCZ-075-PRF 
3/4" Low Flow Valve with 3/4" PR
RBY Filter (Assembled)
Flow: 0.20 to 5 gpm

   


RBY-200SSMX 
200 Mesh Stainless Steel
Replacement Screen

 

Operating Range

  • Flow:
    • XCZ-075-PRF: 0.20 to 5.0 GPM (0.8 to 18.9 l/m)
    • XCZLF-100-PRF: 0.20 to 10.0 GPM (0.8 to 37.85 l/m)
  • Inlet Pressure: 20 to 150 psi (1.4 to 10.3 bar)
  • Regulated Pressure:
    • XCZ-075-PRF: 30 psi (2.1 bar)
    • XCZLF-100-PRF: 40 psi (2.8 bar)
  • Filtration: 200 mesh (75 micron)

Pressure Loss Chart

In order to supply optimum outlet pressure, additional pressure is needed at the inlet since there is some pressure loss from water flowing through the kit. The amount of pressure loss depends on the flowrate.

The charts below list the minimum inlet pressure required to supply optimum outlet pressure.

Minimum Inlet Pressure for Optimum Outlet Pressure
Flow (gpm) Inlet pressure (psi) required to supply 30 psi outlet pressure
XCZ-075-PRF
Inlet pressure (psi) required to supply 40 psi outlet pressure
XCZLF-100-PRF
0.2 34.4 44.4
1.0 36.1 44.4
3.0 38.1 45.0
5.0 43.4 46.2
10 --- 52.2

Metric

Minimum Inlet Pressure for Optimum Outlet Pressure
Flow l/m Inlet pressure (bar) required to supply 2.0 bar outlet pressure
XCZ-075-PRF
Inlet pressure (bar) required to supply 2.8 bar outlet pressure
XCZ-LF-100-PRF
0.8 2.4 3.1
3.8 2.5 3.1
11.4 2.6 3.1
18.9 3.0 3.2
37.9 --- 3.6