Troubleshooting Center

Golf Decoder - “Suspected Ground Fault”

  1. Activate 50/60Hz mode test.
  2. Using a clampmeter, at the downstream (field) side of the MSP-1, compare the mA draw of RED and BLACK wires.
  3. The wire with the higher draw will have leakage.
  4. At LDI, disconnect wire with lower draw and choose point halfway to end of wire path. Measure draw in connected (active) wire. Disconnect any critical path loops before testing.