LP Series Pump Stations

Rain Bird’s LP Series Horizontal End Suction and Vertical multistage pump stations are designed for small to midsize boost, flooded suction and suction lift applications such as city parks and buildings, sports fields, commercial buildings, small homeowners' associations and large residential sites. Its low profile design, durable centrifugal or vertical multistage pump configuration, and choice of options make it an ideal choice for Turf irrigation applications.

Features

Cost effective – Standardized VFD driven pump system in enclosure delivers high performance with minimum investment  
Low Profile – Compact aluminum enclosure with powder-coated skid and piping  
Energy efficient – Variable Frequency Drive (VFD) maintains constant pressure at varying flow demand  
Reliability – Simple, standard design, easy installation and maintenance  
Mechanical Features
Inlet Butterfly Isolation Valve  
Discharge Butterfly Isolation Valve  
Silent Check Valve  
Enclosures / External Connections
Marine-Grade Aluminum Enclosure  
Polyester Powder-Coated Steel Deck and Piping  
Thermostat and Fan on Mechanical Enclosure  
Pump Control
Pump Start Relay  
VFD - Variable Frequency Drive for Control of Pressure  
Display
Monochrome Touch Screen Display

Specs

LP Series – Horizontal End Suction - 1 Pump – Aluminum Enclosure
Motor Size : (5 HP), ( 7.5 HP), (10 HP)
Pump Type: Horizontal End Suction
Power Requirement: (480/60/3 V/HZ/PH), (208-230/60/3 V/HZ/PH), (208-230/60/1 V/HZ/PH)
Inlet Pressure Requirement: Suction Lift or Boost Applications
Outlet Pressure:Up to 100 psi (6.9 bar)
Outlet Flow: Up to 200 gpm (12.6 lps, 45.4 m3/h) 
Inlet / Discharge Size: 3" flange fitting standard - 2" and 4" Flange fitting adapters available
LP Series – Vertical Multistage – 1 Pump – Aluminum Enclosure
Motor Size: (1 HP),  (1.5 HP), (2 HP), (5 HP), (7.5 HP) 
Pump Type: Vertical Multistage
Power Requirement: (480/60/3 V/HZ/PH), (208-230/60/3 V/HZ/PH), (208-230/60/1 V/HZ/PH)
Inlet Pressure Requirement: Suction Lift or Boost Applications  
Outlet Pressure: Up to 120 psi (8.3 bar)   
Outlet Flow: Up to 90 gpm (5.7 lps, 20.4 m3/h)
Discharge Size: 2" flange fitting standard - 3" and 4" adapters available

Dimensions

Concrete Slab Dimensions (min):  65" x 49" (165 cm x 125 cm)  
Platform Skid Dimensions (min): 53" x 39.75" (135 cm x 101 cm)  
LP Series – Horizontal End Suction - 1 Pump – Aluminum Enclosure Cabinet Height: (from slab) 35" (89 cm)  
LP Series – Vertical Multistage – 1 Pump – Aluminum Enclosure Cabinet Height: (from slab) 35" (89 cm) or 47" (107 cm)

Model Comparison

  • Horizontal End Suction - LP Series: 5 to 10 HP; Up to 100 psi (6.9 bar); Up to 200 gpm (12.6 lps, 45.4 m3/h)   
  • Vertical Multistage - LP Series: 1 to 7.5 HP; Up to 120 psi (8.3 bar); Up to 0 gpm (5.7 lps, 20.4 m3/h)